What size air conditioner do I need? Room size chart

11 min read

What size air conditioner do I need? Room size chart

Find the right size air conditioner for your room with a room size chart, what changes the size, and why oversizing costs more.

Short answer

Allow about 120 watts of cooling per square metre for a typical insulated Australian room in 2026, then add for sun, heat and poor insulation: a 2.5 kW split suits a room up to about 20 m², a 3.5 kW about 29 m², a 5 kW about 42 m² and a 7.1 kW about 59 m². West-facing glass or no insulation cuts those areas by a sixth to a quarter.

Prices are estimates, not quotes (how we estimate them). Rebate rules checked September 2026.

Compare 3 quotes for my house

A rule of thumb that is not terrible: about 100 to 140 watts of cooling per square metre in a typical insulated Australian room. A 25 square metre lounge often wants 2.5 to 3.5 kilowatts, not a 7 kilowatt monster.

West-facing glass, a raked ceiling, or no insulation will push that number up. A well-shaded brick home in Melbourne will sit at the low end. Always ask the installer what area they assumed. If they did not ask about windows, they guessed.

Oversizing feels safe. It is how you get a unit that blasts cold for eight minutes, shuts off, and leaves the room clammy. Humidity stays. The compressor short-cycles. The quote was bigger for no comfort.

For ducted, zoning matters more than the headline kilowatt. A system that can idle two bedrooms while the living zone runs will cost less to run than a bigger unit blasting the whole house because the thermostat is in the hallway.

What size air conditioner do I need for my room?

Measure the floor. Length times width, in metres. An open-plan kitchen, dining and lounge counts as one room if there is no door between them, because the air does not know where the rug ends.

Multiply by 120 watts. That is the middle of the 100 to 140 W/m² band most Australian installers work from, and it is the starting number our air conditioner size calculator uses. A 25 m² lounge comes out at 3.0 kW of cooling.

Then adjust for the four things that actually move the load:

  • Sun. Big west-facing glass adds roughly 18 percent. A shaded, south-facing room takes about 10 percent off.
  • Insulation. No ceiling batts or a leaky old house adds roughly 18 percent. A well-sealed, insulated room takes about 5 percent off.
  • Ceiling height. A 2.7 metre ceiling adds about 10 percent. A raked or 3 metre-plus ceiling adds about 20 percent.
  • Climate. Hot places (Queensland, the NT, Perth, inland NSW and SA) add about 10 percent. Melbourne, Hobart and Canberra take a few percent off for cooling, though heating matters more there.

Then pick the smallest standard size that covers the number. If the load sits within about 8 percent of the smaller size, take the smaller size. Inverters stretch. A little under on paper is fine; a lot over is how you buy a clammy room.

Air conditioner room size chart (m² to kW)

This is the calculator's logic laid out as a chart. Standard means average sun, average insulation, a 2.4 metre ceiling and a temperate climate like Sydney or Adelaide.

Split system size by room area, 2026
Room areaTypical roomStandard roomHot climate or big west glassWest glass and poor insulation
10 to 15 m²Bedroom, study2.5 kW2.5 kW2.5 kW
16 to 20 m²Main bedroom2.5 kW2.5 to 3.5 kW3.5 kW
21 to 25 m²Small lounge2.5 to 3.5 kW3.5 kW3.5 to 5.0 kW
26 to 30 m²Lounge3.5 kW3.5 to 5.0 kW5.0 kW
31 to 40 m²Living and dining3.5 to 5.0 kW5.0 to 7.1 kW5.0 to 7.1 kW
41 to 50 m²Open plan5.0 to 7.1 kW7.1 kW7.1 to 9.4 kW
51 to 60 m²Large open plan7.1 kW7.1 to 9.4 kW9.4 kW or two units
Over 60 m²Whole floorPrice multi-head or ductedPrice multi-head or ductedPrice multi-head or ducted
Based on 120 W/m², plus about 18% for big west-facing glass and about 18% for poor or no insulation. Add about 10% for a 2.7 m ceiling and 20% for raked ceilings. Sizes are the standard capacities sold in Australia; some brands also sell 2.0, 6.0 and 8.0 kW models. An installer's heat-load check on site beats any chart.

What size room will a 2.5 kW split system cool?

A 2.5 kW split cools a standard room of up to about 20 m². That is a bedroom, a study or a small lounge. Put the same unit in a west-facing room with big glass and it tops out nearer 18 m². Add poor insulation to that and call it 15 m².

It is the smallest common wall split and the cheapest to buy. A 2.5 kW unit on a straightforward back-to-back wall is usually $1,500 to $2,500 installed in 2026. It is also the unit people most often regret buying for a lounge, because on a 40 degree afternoon it runs flat out and still loses. Most brands also sell a 2.0 kW for small bedrooms, though the price saving over a 2.5 kW is usually small.

Is 2.5 kW enough for a bedroom? For a normal 10 to 16 m² bedroom, yes, and it will run quietly at low speed most of the night. That quiet is the point. See our quiet bedroom air conditioner guide if noise is the worry.

What size room will a 3.5 kW air conditioner cool?

A 3.5 kW split cools a standard room of up to about 29 m². In a sunny west-facing room, about 25 m². With west glass and poor insulation, about 21 m².

This is the most sensible size for a large main bedroom or a normal lounge in a brick veneer home. It usually costs only a few hundred dollars more than a 2.5 kW, often $1,700 to $2,700 installed on a simple wall, and it gives you headroom on the handful of days a year when it matters.

Is 3.5 kW enough for a living room? For a closed lounge under about 29 m², yes. For an open-plan kitchen, dining and living space, almost never. Measure the whole open area, not the bit with the couch.

What size room will a 5 kW, 7 kW or 8 kW split system cool?

A 5.0 kW split cools a standard room of up to about 42 m², or about 35 m² with big west glass. It is the default for a living and dining room.

A 7.1 kW split, the size most people mean when they search for a 7 kW split system, cools a standard room of up to about 59 m². With big west glass that drops to about 50 m², and with west glass and poor insulation to about 42 m². This is the open-plan unit. A 5 to 7 kW split is usually $2,100 to $3,900 installed in 2026 on a standard install, with a 7.1 kW on its own more like $2,600 to $3,900. Two storey pipe runs, double brick and new circuits add to that. For your wall and your switchboard, get up to three local quotes.

An 8 kW split covers up to about 67 m² in a standard room, or about 56 m² with west glass. Not every brand makes one; many jump from 7.1 kW to 8.0 or 8.5 kW and then to 9.4 kW. Past about 60 m² of open plan, one big wall unit starts losing to two smaller heads or a ducted system, because a single outlet cannot throw air evenly into the far corners. Price both before you buy. Our multi-head and ducted comparison covers the trade-offs.

Largest room each split size suits
Unit sizeStandard roomHot climate or big west glassWest glass and poor insulation
2.5 kWabout 20 m²about 18 m²about 15 m²
3.5 kWabout 29 m²about 25 m²about 21 m²
5.0 kWabout 42 m²about 35 m²about 30 m²
7.1 kWabout 59 m²about 50 m²about 42 m²
8.0 kWabout 67 m²about 56 m²about 48 m²
9.4 kWabout 78 m²about 66 m²about 56 m²
Calculated at 120 W/m² with the same sun and insulation loadings as the chart above, 2.4 m ceilings. Raked ceilings cut these areas by roughly a sixth.

One thing that trips up 7 kW buyers: the electrical side. The unit's installation manual sets the circuit breaker and cable size, and a licensed electrician decides whether your switchboard can carry it or whether it needs a dedicated circuit. Larger splits often do. Budget about $300 to $900 for a new circuit, and $1,000 to $3,500 on top if the switchboard itself needs upgrading.

What is 2.5 HP in kW? Converting horsepower and BTU

Australian units are sold in kilowatts of cooling. Imported listings and some older installers still talk in horsepower (HP) or BTU. The conversion from BTU is exact: 1 kW equals about 3,412 BTU per hour. The horsepower figure is a trade convention, not a physics one, and it varies a little between brands.

Air conditioner HP, BTU and kW (approximate)
Horsepower (trade term)BTU per hourCooling capacityStandard room it suits
1 HPabout 9,000about 2.5 to 2.6 kWup to about 20 m²
1.5 HPabout 12,000about 3.5 kWup to about 29 m²
2 HPabout 18,000about 5.0 to 5.3 kWup to about 42 m²
2.5 HPabout 24,000about 7.0 kWup to about 59 m²
3 HPabout 27,000 to 30,000about 8.0 to 8.5 kWup to about 67 m²
BTU to kW is a fixed conversion (1 kW ≈ 3,412 BTU/h). The HP column is a common industry convention only; check the rated cooling kW on the spec sheet or energy label before you compare quotes.

So a 2.5 HP aircon is a 7 kW class unit, and it suits an open-plan room of up to about 59 m² in a standard house. A 2 HP unit is a 5 kW class unit and suits up to about 42 m². If a listing only gives HP, ask for the rated cooling and heating capacity in kW. If they cannot give it, keep scrolling.

Is it better to oversize or undersize an air conditioner?

Slightly undersized beats badly oversized. Badly undersized is worse than both.

An oversized split hits the set temperature fast, throttles down to its minimum, and if the minimum is still too much for the room it cycles off and on. The air gets cold before the coil has run long enough to pull moisture out, so the room feels cool and clammy. You paid more for the unit, you often pay more to run it, and it is louder at the start of every cycle.

A modern inverter that is a touch small just runs longer at a steady speed. On the three hottest days of the year the room might sit at 26°C instead of 24°C. The other 360 days it runs in its most efficient range.

An undersized unit, a 2.5 kW in a 35 m² lounge, runs flat out for hours and never gets there. That is the one to avoid. The chart above exists so you land in the sensible middle.

The upsell usually sounds like this: "Go up a size, just to be safe." Ask what load they calculated and what they assumed about windows and insulation. If the answer is a shrug, you are paying for their safety margin. Get up to three licensed installers to size it for your actual rooms.

What size ducted air conditioning do I need for a 3 or 4 bedroom house?

Ducted is sized on the whole conditioned area, but not at the full 120 W/m² for every room. You never cool every zone at full load at once, and a zoned system is designed around that. As a rough guide for a single storey home with ceiling insulation:

Ducted reverse cycle size by home, rough guide
HomeConditioned areaTypical ducted capacityTypical installed price, 2026
3 bedroom, single storeyabout 120 to 160 m²about 10 to 14 kW$9,000 to $16,000
4 bedroom, single storeyabout 160 to 220 m²about 14 to 17 kW$12,000 to $18,000
Two storey or tight roof, any sizevariesoften two systems or 16 kW and up$13,000 to $20,000 or more
Rules of thumb only. A ducted quote should come with a room-by-room heat-load calculation, the zone layout and the return-air position. West-facing living areas, raked ceilings and poor insulation push capacity up.

Two things matter more than the headline kW. First, zoning, so you can run the living zone in the afternoon and the bedrooms at night instead of the whole house. Second, where the thermostat lives. A hallway sensor in a four bedroom house is how a 16 kW system ends up cooling the linen press. Our ducted air conditioning cost guide breaks the price down by home size, and the Victorian rebate page covers the discount if you are replacing gas ducted heating. A ducted quote should start with someone in your roof space, so ask for a local ducted quote rather than a phone estimate.

How to check an installer's sizing on a quote

  • The quote names the rated cooling and heating capacity in kW, not just a model family.
  • The installer asked about the room area, ceiling height, which way the windows face, and insulation. If they sized it from the driveway, they guessed.
  • For open plan, they measured the whole connected space.
  • For ducted, you get a zone plan and a return-air location, not just a number of outlets.
  • If they recommend a size bigger than the chart, they can tell you why in one sentence.

Run your rooms through the size calculator before anyone visits, then compare. When two quotes disagree by one size, ask each installer to explain the other's number. The one who can is usually the one to hire. Once you know the size, the running cost calculator shows what it will cost per hour, and up to three licensed installers can confirm it on site.

Want a number for your house? Check the rebate on your postcode. No name required. Check the rebate on your postcode.

Or do the sums yourself first: what size you need and what it costs to run.

Sources

FAQ

Common questions

What size room will a 2.5 kW air conditioner cool?

About 20 m² in a standard insulated room with average sun. With big west-facing glass it is closer to 18 m², and with west glass and poor insulation about 15 m². That makes it a bedroom or study unit, not a living-room unit.

What area does a 7 kW air conditioner cover?

A 7.1 kW split covers up to about 59 m² of standard room, about 50 m² with big west-facing glass, and about 42 m² with west glass and poor insulation. Past about 60 m² of open plan, price a multi-head or ducted system as well.

What size room will a 3.5 kW air conditioner cool?

Up to about 29 m² in a standard room, about 25 m² with strong western sun, and about 21 m² if the room also has poor insulation. It suits a large bedroom or a closed lounge.

What size room is a 2.5 HP aircon suitable for?

A 2.5 HP unit is roughly a 7 kW class air conditioner, so it suits an open-plan room of up to about 59 m² in a standard home. HP is a loose trade term, so check the rated cooling capacity in kW on the spec sheet before comparing.

How many square metres can a 2 HP aircon cool?

A 2 HP unit is about 5 kW of cooling, which suits up to about 42 m² in a standard room or about 35 m² with big west-facing windows. Confirm the kW rating, because HP labels vary between brands.

Is it better to oversize or undersize an AC unit?

Slightly undersized is usually better than oversized for a modern inverter split. An oversized unit short-cycles and leaves the room cold but clammy, while a unit that is a touch small runs longer at an efficient steady speed. A badly undersized unit that runs flat out and never reaches temperature is the one to avoid.

How much does it cost to run a 2.5 kW aircon per hour?

A modern 2.5 kW inverter split typically draws about 0.4 kW of electricity in an average running hour, so about 11 to 17 cents an hour at 2026 default-offer flat rates of roughly 28 to 42 cents per kWh. Our running costs guide shows the working for every size.

How do I work out what size air conditioner I need?

Multiply the room's floor area in square metres by about 120 watts, then add roughly 18% for big west-facing glass, 18% for poor insulation and 10 to 20% for high or raked ceilings. Pick the smallest standard size that covers the result, or use our size calculator, which does the same sums.

A quiet Australian living room

Get quotes for your air con